FAPELEC · TOSUNLUXDatasheet — 22 kW wall charger for electric carsfapelec.ma/en/produits/maison-batiment/chargeur-voiture-electrique/ · 22/10/2026
- Home
- Home & building
- Electric mobility
- 22 kW wall charger for electric cars

Series · Charging station · 22 kW
22 kW wall charger for electric cars
Up to 22 kW · three-phase 400 V · IP55
IEC 61851-1
TOSUNLUX (Tosun) wall-mounted charging station for electric cars, for installation in a garage, villa, company or hotel car park: up to 22 kW three-phase 400 V, charging current adjustable from 10 to 32 A, IP55 housing for indoor and outdoor use, monitoring display and charging cable with vehicle connector.
IEC 61851-1IEC 62196-2
22 kWPower
Three-phase 400 VNetwork
IP55Protection
Technical characteristics
| Charging power | Up to 22 kW |
|---|---|
| Power supply | Three-phase 400 V · range 360 – 440 V |
| Charge current | Adjustable from 10 to 32 A |
| Current at 22 kW | 32 A per phase at 400 V (P = √3 × 400 V × 32 A = 22.2 kW)1 |
| Single-phase power | 7.4 kW at 230 V and 32 A1 |
| Type | Wall-mounted AC charging station, mode 32 |
| Vehicle connector | 7-contact Type 2 |
| Interface | Front-panel screen · status light bar |
| Display | “400V-FAST” screen and status lights |
| Mounting | Wall-mounted · socket holder on the front |
|---|---|
| Charging cable | 5 m, attached to the charging station2 |
| IP rating | IP55 |
|---|
| Manufacture | Under the supervision of TOSUN (Germany) GmbH |
|---|---|
| Standard / marking | IEC 61851-1 · IEC 62196-23 |
| Compatibility | All electric and plug-in hybrid vehicles with Type 2 socket |
|---|---|
| Indicative charging time | 3 h for 60 kWh at 22 kW, if the vehicle's on-board charger accepts 22 kW1 |
| Installation | Dedicated three-phase line; TOSUN UKP 32 A switch-disconnector upstream |
| Line protection | 4P 40 A curve C circuit breaker and 30 mA type A residual current device with 6 mA DC detection (or type B), according to IEC 61851-1 and NF C 15-1002 |
| Power cable | 5G6 mm² copper up to 30 m (to be checked against voltage drop)2 |
- 1 Calculated value: P = √3 U I (three-phase) · P = U I (single-phase) · t = E / P (U = 400 V / 230 V, I = 32 A, E = 60 kWh).
- 2 Value from an equivalent series, to be confirmed when ordering.
- 3 Normative value: IEC 61851-1 · IEC 62196-2.
22 kW wall charger for electric cars — TOSUNLUX Moroccofapelec.ma