TOSUNLUX NT00 fuse and base
Series · Fuse · NT

NT blade fuses

NT00 · NT0 · NT1 · NT2 · 63 → 400 A · gG

63–400 A · IEC 60947-3

TOSUNLUX (Tosun) NT (NH) gG fuse links from 63 to 400 A in sizes NT00 to NT2, 500 V, breaking capacity 120 kA, for protecting switchboard outgoing feeders; bases, neutral links and handle available as accessories.

IEC 60947-3IEC 60269
63–400 ARated currents
NT00 → NT2Sizes
IEC 60269Standard
PDF datasheet

Reference selector

18 references
Compare
NT0063 A500/660 V4.6 WSist 101 · 160 A
NT0080 A500/660 V6 WSist 101 · 160 A
NT00100 A500/660 V7.3 WSist 101 · 160 A
NT00125 A500 V7.6 WSist 101 · 160 A
NT00160 A500 V9.6 WSist 101 · 160 A
NT063 A500/660 V6.9 WSist 160 · 160 A
NT080 A500/660 V7.6 WSist 160 · 160 A
NT0100 A500/660 V8.9 WSist 160 · 160 A
NT0125 A500 V10.1 WSist 160 · 160 A
NT0160 A500 V15.2 WSist 160 · 160 A
NT1160 A500 V13 WSist201 · 250 A
NT1200 A500 V15.2 WSist201 · 250 A
NT1250 A500 V18.3 WSist201 · 250 A
NT2200 A500 V15 WSist401 · 400 A
NT2250 A500 V18.4 WSist401 · 400 A
NT2300 A500 V21 WSist401 · 400 A
NT2355 A500 V24.5 WSist401 · 400 A
NT2400 A500 V26 WSist401 · 400 A

Also searched as: NT00 · NT0 · NT1 · NT2

Selection tables

Power dissipation

NT00 63ANT00634.613.8Sist 101 · 160 A
NT00 80ANT0080618.0Sist 101 · 160 A
NT00 100ANT001007.321.9Sist 101 · 160 A
NT00 125ANT001257.622.8Sist 101 · 160 A
NT00 160ANT001609.628.8Sist 101 · 160 A
NT0 63ANT0636.920.7Sist 160 · 160 A
NT0 80ANT0807.622.8Sist 160 · 160 A
NT0 100ANT01008.926.7Sist 160 · 160 A
NT0 125ANT012510.130.3Sist 160 · 160 A
NT0 160ANT016015.245.6Sist 160 · 160 A
NT1 160ANT11601339.0Sist201 · 250 A
NT1 200ANT120015.245.6Sist201 · 250 A
NT1 250ANT125018.354.9Sist201 · 250 A
NT2 200ANT22001545.0Sist401 · 400 A
NT2 250ANT225018.455.2Sist401 · 400 A
NT2 300ANT23002163.0Sist401 · 400 A
NT2 355ANT235524.573.5Sist401 · 400 A
NT2 400ANT24002678.0Sist401 · 400 A

Power dissipation at In, to be included in the cabinet heat balance (IEC 61439).

Technical characteristics

Electrical
SizesNT00 · NT0 · NT1 · NT2
Rated currents in the FAPELEC catalogue63 – 400 A
Rated voltage500/660 V (≤ 100 A) · 500 V (≥ 125 A)
TypeNH gG blade fuse links
Mechanical
Dimensions and mountingNT00: 78 × 30 × 54 mm → NT2: 150 × 60 × 75 mm · screw-fixed bases
Compliance
StandardIEC 60269
Cartridge marking500 V~ · 120 kA · gG-gL
  1. 1 Value from an equivalent series, to be confirmed when ordering.

Documentation

  • DatasheetFusibles NT à couteauFRPDF · 431 kBDownload
  • Datasheetمصهرات NT بسكاكينARPDF · 370 kBDownload
  • Certificate · CE conformity verificationIntertek · 2312A1212SHA-V1 · EN IEC 60947-3:2021ENWebP · 232 kBDownload
  • Certificate · CB test certificate (IECEE)Intertek Semko · SE-113236 · IEC 60947-3:2020ENWebP · 157 kBDownload
  • Manufacturer certificateQuanpin Certification (CNAS · IAF) · ISO 9001:2015ENWebP · 236 kBDownload
Esc
↑ ↓ navigate · ↵ open · Esc close