Series · Contactor starter · TSE1-D
TSE1-D enclosed starters
9 to 32 A · coil 220 V or 380 V
9–32 A · IEC 60947-4-1
TOSUNLUX (Tosun) TSE1-D enclosed starters: direct-on-line starters in an enclosure with start / stop buttons on the front, for remote control and frequent starting of motors on 50 / 60 Hz networks up to 550 V. To be combined with the TSR2-D thermal overload relay suited to the motor.
IEC 60947-4-1
9–32 ACurrent
up to 15 kWMotor AC-3
220 / 380 VCoil
Reference selector
5 referencesNo references match these filters.
Also searched as: TSE1-D · D09 · D12 · D18 · D25 · D32
Selection tables
Selection table
| 9 | 4 | TSR2-D1312 · TSR2-D1314 | 5.5 – 8 A · 7 – 10 A | |
| 12 | 5.5 | TSR2-D1316 | 9 – 13 A | |
| 18 | 7.5 | TSR2-D1321 | 12 – 18 A | |
| 25 | 11 | TSR2-D1322 · TSR2-D2353 | 17 – 25 A · 23 – 32 A | |
| 32 | 15 | TSR2-D1353 · TSR2-D2355 | 23 – 32 A · 28 – 36 A |
Reference configurator
Choose the rated current and the coil voltage: the full reference is displayed, ready to copy.
Full reference
Order code
Full reference = contactor reference + coil code. Example: TSE1-D09 + M7 = TSE1-D09M7, 220 V 50/60 Hz coil. Standard coils: 220 V (M7) · 380 V (Q7).
| Coil voltage (V) | 24 | 42 | 48 | 110 | 220 | 230 | 240 | 380 | 400 | 415 | 440 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 50 Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 | Q5 | V5 | N5 | R5 |
| 60 Hz | B6 | D6 | E6 | F6 | M6 | — | U6 | Q6 | — | — | R6 |
| 50/60 Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 | Q7 | V7 | N7 | R7 |
Technical characteristics
| Type | Contactor starter (direct-on-line starter) in enclosure |
|---|---|
| Mains voltage | Up to 550 V · 50 / 60 Hz |
| Power AC-3 · 415 V | 4 · 5.5 · 9 · 11 · 15 kW |
| Power AC-3 · 440 V | 4 · 5.5 · 9 · 11 · 15 kW |
| Power AC-3 · 550 V | 5.5 · 7.5 · 10 · 15 · 18.5 kW |
| Rated operational current AC-4 (400 V) | 3.5 A (D09) → 12 A (D32)1 |
| Rated operational current AC-1 | 25 A (D09) → 50 A (D32)1 |
| Rated insulation voltage Ui | 690 V1 |
| Rated impulse withstand voltage Uimp | 6 kV2 |
| Contacts | 3 poles + 1 NO self-holding1 |
| Control | On (I) and off (O) buttons on the front |
| TOSUN coil voltages | 24 · 42 · 48 · 110 · 220 · 230 · 240 · 380/400 · 415 · 440 V — 50/60 Hz |
| Coil codes | 220 V: M7 · 380/400 V: Q7 |
| Thermal protection | TSR2-D relay to be selected according to the motor |
| Mechanical endurance | 10 × 10⁶ operations1 |
|---|---|
| Electrical endurance AC-3 / AC-4 | AC-3: 1 × 10⁶ · AC-4: 0.2 × 10⁶ operations1 |
| Dimensions A × B × C and fixing | 105 × 165 × 115 mm · IP55 enclosure · wall mounting with 4 screws1 |
| Product standard | IEC 60947-4-13 |
|---|
- 1 Value from an equivalent series, to be confirmed when ordering.
- 2 Normative value: IEC 60947-1, table H.1: 230/400 V system → 4 kV (cat. II/III modular), 6 kV (cat. III), 8 kV (cat. IV, Ue 690 V).
- 3 Normative value: IEC 60947-4-1.