TOSUNLUX TSC-D09 white contactor 9 A
Series · Contactor · LC-D White

LC-D White contactors — TSC-D

LC-D09 → TSC-D32 · TSC-D09 → TSC-D32 · 9–32 A · 4–15 kW

IEC 60947-4-1

TOSUNLUX (Tosun) TSC-D series AC contactors, white housing (listed as “LC-D White” in the FAPELEC catalogue), for making, breaking and frequent control of AC motors on circuits up to 660 V AC 50/60 Hz. Five ratings from 9 to 32 A in AC-3 (4 to 15 kW at 400 V), 220 V coil. Can be combined with an auxiliary block, a timer, a mechanical interlock and, with a thermal overload relay, used as an electromagnetic starter.

EN 60947-5-1IEC 60947-4-1IEC 60947-5-1
9–32 AIe AC-3
4–15 kWMotor 400 V
220 VCoil
PDF datasheet

Reference selector

5 references
Compare
9 A3.5 A2.2 kW4 kW20 A3P+NO or 3P+NC220 V
12 A5 A3 kW5.5 kW20 A3P+NO or 3P+NC220 V
18 A7 A4 kW7.5 kW32 A3P+NO or 3P+NC220 V
25 A8.5 A5.5 kW11 kW40 A3P+NO or 3P+NC220 V
32 A12 A7.5 kW15 kW50 A3P+NO or 3P+NC220 V

Dimensions A × B × C: D09-D12 47 × 76 × 82 mm · D18 47 × 76 × 87 mm · D25 57 × 86 × 95 mm · D32 57 × 86 × 100 mm.

Selection tables

Selection table

943.5203P+NO or 3P+NC47 × 76 × 82
125.55203P+NO or 3P+NC47 × 76 × 82
187.57323P+NO or 3P+NC47 × 76 × 87
25118.5403P+NO or 3P+NC57 × 86 × 95
321512503P+NO or 3P+NC57 × 86 × 100

Reference configurator

Choose the rated current and the coil voltage: the full reference is displayed, ready to copy.

Full reference

Order code

Full reference = contactor reference + coil code. Example: TSC-D09 + M7 = TSC-D09M7, 220 V 50/60 Hz coil. Standard coils: 220 V (M7).

Coil voltage (V)244248110220230240380400415440
50 HzB5D5E5F5M5P5U5Q5V5N5R5
60 HzB6D6E6F6M6—U6Q6——R6
50/60 HzB7D7E7F7M7P7U7Q7V7N7R7

Associations

TSR2-D1312 · TSR2-D13145.5 – 8 A · 7 – 10 ATSE1-D09
TSR2-D13169 – 13 ATSE1-D12
TSR2-D132112 – 18 ATSE1-D18
TSR2-D1322 · TSR2-D235317 – 25 A · 23 – 32 ATSE1-D25
TSR2-D1353 · TSR2-D235523 – 32 A · 28 – 36 ATSE1-D32

TSR2-D thermal overload relay mounted directly below the contactor. Front-mounted add-on blocks common to all ratings: auxiliary contacts TSA1-DN11 (NO + NC) · TSA1-DN22 (2NO + 2NC), pneumatic timers TSA2-DT2 · TSA2-DT4 (on-delay) and TSA3-DR2 (off-delay).

Contactor comparison

TSC1-K9 – 12 A660 V6 kV10 × 10⁶ operations3P + NO / NC24 V AC / DC · 220 V coilsSmall motors up to 5.5 kW, compact enclosures
TSC-D9 – 32 A660 V6 kV8 – 10 × 10⁶ operations3P + NO / NCTSR2-D relays · TSA1 / TSA2 blocksMotors up to 15 kW, general use
TSC79 – 32 A660 V6 kV10 × 10⁶ operations3P + NO + NCTSR2-D relays · TSC7 coilsCompact boards, integrated NO + NC
TSC1-D9 – 150 A660 V6 kV (D09 – D95) · 8 kV6 – 10 × 10⁶ operations3P + NO / NC · 4PTSR2-D relays · TSA1 / TSA2 / TSA3 blocks · TSX1 coilsIndustry: motors up to 75 kW, reversing, star-delta
TSC1-F115 – 150 A1 000 V8 kV10 × 10⁶ operations3P + 1 NO + 1 NC220 V · 380 V coilsLarge motors 55 – 75 kW, AC-1 distribution up to 250 A
LCH8AC-7a 25 – 63 A400 V4 kV1 × 10⁶ operations2P · 4P NO / NCAC coils 24 · 110 · 230 VCommercial and residential: lighting, heating, load shedding in modular boards

Dimensions and fixing

Dimensions and fixing
47768211334/3550/604.5
47768211334/3550/604.5
47768711834/3550/604.5
57869512640484.5
578610013140484.5

Dimensions in mm. A × B × C: width × height × depth · D: depth with add-on block · a × b: fixing centres · Ø: fixing holes.

Technical characteristics

Electrical
TypeElectromagnetic AC contactor, white housing
Poles · contacts3P+NO or 3P+NC
Max. rated operational voltage660 V AC
Frequency50 / 60 Hz
Ie AC-39 – 32 A
Ie AC-43.5 – 12 A
Motor power AC-3 400 V4 – 15 kW
Thermal current Ith20 – 50 A
Rated operational current AC-120 A (D09, D12) → 50 A (D32) · equal to Ith
Rated insulation voltage Ui690 V
Rated impulse withstand voltage Uimp6 kV
TOSUN coil voltages24 – 600 V AC
Coil in the FAPELEC catalogue220 V
Mechanical
Electrical endurance AC-30.8 – 1 × 10⁶ operations
Electrical endurance AC-40.2 × 10⁶ operations
Mechanical endurance8 – 10 × 10⁶ operations
Dimensions A × B × C47 × 76 × 82 mm (D09) → 57 × 86 × 100 mm (D32)
Compliance
Standard (CE and CB certificates)IEC 60947-4-1
BodyIntertek
  1. 1 Calculated value: Ie AC-1 = Ith (conventional thermal current published by TOSUNLUX).
  2. 2 Value from an equivalent series, to be confirmed when ordering.
  3. 3 Normative value: IEC 60947-1, table H.1: 230/400 V system → 4 kV (cat. II/III modular), 6 kV (cat. III), 8 kV (cat. IV, Ue 690 V).

Documentation

  • DatasheetContacteurs LC-D White — TSC-DFRPDF · 532 kBDownload
  • Datasheetكونتاكتورات LC-D White — TSC-DARPDF · 452 kBDownload
  • Certificate · CE conformity verificationIntertek · 210200110SHA-V1 · EN IEC 60947-4-1:2019 · EN 60947-5-1:2017ENWebP · 175 kBDownload
  • Certificate · CB test certificate (IECEE)Intertek Semko · SE-104717 · IEC 60947-4-1:2018 · IEC 60947-5-1:2016ENWebP · 58 kBDownload
  • Manufacturer certificateQuanpin Certification (CNAS · IAF) · ISO 9001:2015ENWebP · 236 kBDownload