TOSUNLUX TDP-1 voltage protector
Series · Voltage protector · TDP

TDP-1 · TDP-3 min/max voltage monitoring relays

TDP-1 1P · TDP-3 3P · 32–80 A

IEC 60947-1

TOSUNLUX (Tosun) modular digital overvoltage and undervoltage protectors: fast disconnection of the power supply in the event of overvoltage, undervoltage or phase loss, followed by time-delayed automatic reconnection when normal voltage returns. Front-panel voltage display. TDP-1 single-phase 220 V and TDP-3 three-phase 380 V, from 32 to 80 A.

IEC 60947-1IEC 60947-5-1
32–80 ACurrent
230–300 VOvervoltage
120–210 VUndervoltage
PDF datasheet

Reference selector

8 references
Compare
1P220 V~32 A6.6 kVA
1P220 V~40 A8.8 kVA
1P220 V~63 A13 kVA
1P220 V~80 A17 kVA
3P380 V~32 A20 kVA
3P380 V~40 A25 kVA
3P380 V~63 A40 kVA
3P380 V~80 A52 kVA

Maximum load power given by the manufacturer (resistive load). TDP-1: 220 V × In; TDP-3: √3 × 380 V × In, rounded down.

Also searched as: TDP-1 · TDP-3 · TDP1 · TDP3

Selection tables

Selection table

1P220 V~326.6 kVA
1P220 V~408.8 kVA
1P220 V~6313 kVA
1P220 V~8017 kVA
3P380 V~3220 kVA
3P380 V~4025 kVA
3P380 V~6340 kVA
3P380 V~8052 kVA

Monitoring relay function matrix

FunctionTDP-1 · TDP-3TDP-2TDP-4JL-VPTRV8TRL8TRT8
Overvoltage
Undervoltage
Overcurrent
Phase sequence and phase loss
Phase imbalance
Liquid level
Output time delay
Automatic reconnection
Integrated power breaking
Output contact
DIN rail mounting

● function provided.

Connection diagram

Connection diagram

Installed after the service circuit breaker, at the head of the installation to be protected. TDP-3: 3P + N connection, the voltage of each phase is monitored with respect to neutral.

Selection guide — worked example

Villa with a single-phase 220 V connection, subscribed power 8 kVA. I = 8,000 / 220 = 36 A, hence TDP-1 40 A (max. load power 8.8 kVA). Recommended settings: overvoltage 250 V, undervoltage 180 V, automatic reconnection 180 s, the time needed for the air-conditioning compressors to equalise.

Technical characteristics

Electrical
Rated voltageTDP-1: 220 V~ · TDP-3: 380 V~
Currents in the FAPELEC catalogue32 · 40 · 63 · 80 A
Self-consumption≤ 3 W
Rated insulation voltage415 V (Ui)
Rated impulse withstand voltage2.5 kV (Uimp)
Conventional thermal current80 A (Ith)
Utilisation categoryAC-12
Overvoltage threshold230 – 300 V adjustable (TDP-1: 400 V temporary)
Overvoltage cut-off delay0.01 s
Undervoltage threshold120 – 210 V adjustable
Monitored quantity (TDP-3)Phase-to-neutral voltage of each phase — 3P+N connection, neutral mandatory
Undervoltage cut-off delay0.1 s
Reconnection time delay10 – 600 s
FunctionsDisconnection on overvoltage and undervoltage · time-delayed automatic reconnection
Accuracy± 2 %
Mechanical
Dimensions TDP-1 (w × h × d)52 × 84 × 75 mm
Dimensions TDP-3 (w × h × d)90 × 85 × 76 mm
Environment
Ambient temperature−20 … +40 °C
Pollution degree3
Degree of protectionIP20
Compliance
Product standardIEC 60947-1 · IEC 60947-5-1
  1. 1 Value from an equivalent series, to be confirmed when ordering.

Documentation

  • DatasheetRelais de contrôle min/max de tension TDP-1 · TDP-3FRPDF · 493 kBDownload
  • Datasheetمرحلات مراقبة الجهد TDP-1 · TDP-3ARPDF · 369 kBDownload
  • Certificate · CE attestation of conformityBureau Veritas LCIE · yy66As08BWQN64749A1 · EN IEC 60947-1:2021 · EN IEC 60947-5-1:2025ENWebP · 246 kBDownload
  • Manufacturer certificateQuanpin Certification (CNAS · IAF) · ISO 9001:2015ENWebP · 236 kBDownload
Frequently asked questions

Frequently asked questions — TDP-1 · TDP-3 min/max voltage monitoring relays

Which TDP should I choose for a single-phase villa?

The TDP-1, single-phase 220 V. Example from the selection guide: a villa on 220 V with a subscribed power of 8 kVA, I = 8,000 / 220 = 36 A, hence a TDP-1 40 A (max. load power 8.8 kVA). The TDP-1 is available in 32, 40, 63 and 80 A.

What is the difference between the TDP-1 and the TDP-2?

Both disconnect the supply on overvoltage or undervoltage and reconnect automatically. The TDP-2 also monitors the current: it trips on overcurrent (setting from 1 A up to In), displays voltage and current, and has an output contact (1NO on the TDP-2-1, 3NO on the TDP-2-3). The TDP-1 is available from 32 to 80 A, the TDP-2-1 in 40 and 63 A.

Does the TDP reconnect by itself?

Yes. After tripping, it reconnects automatically once the voltage is back to normal, after an adjustable time delay of 10 to 600 s. The selection guide recommends 180 s where air-conditioning compressors are installed.

Which voltage thresholds can be set?

Overvoltage from 230 to 300 V (trips in 0.01 s) and undervoltage from 120 to 210 V (trips in 0.1 s). The TDP-3 monitors the phase-to-neutral voltage of each phase: 3P+N connection, neutral required.

Where is the TDP installed, and is it certified?

On a DIN rail, after the incoming supply circuit breaker, at the head of the installation to be protected. The TDP-1 and TDP-3 hold a CE attestation of conformity issued by Bureau Veritas LCIE (EN IEC 60947-1 and EN IEC 60947-5-1).